BPC-157
Certificate of Analysis
| Current Batch Identity | BC10-2512A |
| Testing Ordered | 19/12/25 |
| Sample recived | 22/01/25 |
| Analysis Conducted | 27/01/25 |
| Product Batch Information | |
|---|---|
| Product Name | BPC-157 10mg |
| Batch Number | BC10-2512A |
| Verified Quantity In Vial | 10.70mg |
| Verified Purity Of Batch | 99.429% |
| Manafacturer | Be Better Peptides LTD |
| Manufacture date | |
| Tested Date | 27/01/2026 |
| Testing Laboratory | Janoshik sro LTD |
| verification Key | M67VV9C6WBZ5 |
🧪 About This Test
This batch of BPC-157 was independently analysed by Janoshik using HPLC (High-Performance Liquid Chromatography). The analysis assesses the identity, amount and peptide purity of the submitted sample, with results reported for the specific batch tested.
The testing method uses chromatographic separation to analyse the target BPC-157 peptide and determine its measured amount and purity.
🔬Testing Laboratory Credentials
Shop this batch - BPC-157
Frequently asked questions
What is a Certificate of Analysis (COA) in Peptides ?
A Certificate of Analysis (COA) is a laboratory document containing analytical results for a specific product batch or lot. It identifies the material tested, the batch reference, testing methods and the results obtained from the analysis. For research peptides, a COA may include information such as peptide identity, amount and purity, depending on the tests performed.
Why is a certificate of Analysis important ?
A COA provides documented analytical information about a specific batch rather than relying solely on a product specification or supplier declaration. It allows the reported testing method and results to be reviewed and provides traceability between the laboratory report and the batch tested.
What does third-party laboratory testing mean for BPC-157 ?
Third-party laboratory testing means the BPC-157 sample was analysed by an external laboratory rather than relying solely on internal testing. In this case, the sample was submitted to Janoshik for independent analytical testing, with the original laboratory report provided alongside the results.
Does this BPC-157 COA apply to every batch ?
No. A Certificate of Analysis is batch-specific. The results shown on this page relate to the particular BPC-157 sample and batch identified on the certificate. A different batch requires its own analytical documentation if it has been independently tested.
How can I verify this BPC-157 Certificate of Analysis?
The Janoshik report contains identifying information that can be used to verify the laboratory record through Janoshik’s verification system. The task number and unique verification key associated with the test can be used to check the corresponding report. Janoshik provides a dedicated online verification system for its reports.
How is BPC-157 tested?
The BPC-157 sample was analysed by Janoshik using High-Performance Liquid Chromatography (HPLC). The analysis assesses the identity, measured amount and peptide purity of the submitted sample.
What is HPLC testing for BPC-157 ?
HPLC, or High-Performance Liquid Chromatography, is an analytical technique used to separate and analyse components within a sample. For peptide testing, the resulting chromatographic profile can be used to assess the target peptide and determine its reported purity and amount.
What does BPC-157 peptide purity mean?
The reported peptide purity represents the proportion of the analysed material identified as the target BPC-157 peptide using the laboratory’s analytical method. It is reported as a percentage and relates specifically to the sample submitted for testing.
What does the BPC-157 amount result mean?
The amount result reports the quantity of BPC-157 detected in the submitted vial, expressed in milligrams. This is a measurement of the material analysed by the laboratory and is separate from the peptide purity percentage.
🧪 About This Test (expanded)
The submitted BPC-157 sample was independently analysed by Janoshik using HPLC (High-Performance Liquid Chromatography). The analysis assesses the identity, measured amount and peptide purity of the submitted GHK-Cu sample.
Testing Method
HPLC is an analytical laboratory technique used to separate and analyse components within a sample. For peptide analysis, the resulting chromatographic profile is used to assess the target peptide and distinguish it from other detectable components.
For BPC-157 analysis, Janoshik’s published testing procedure reports the amount of BPC-157 in milligrams per vial together with the peptide purity percentage for lyophilised samples.
What Is Analysed?
The analysis assesses three principal characteristics of the submitted sample:
Identity
The analysis assesses whether the material corresponds to the specified BPC-157 peptide.
Amount
The quantity of BPC-157 detected in the submitted sample is measured and reported in milligrams per vial.
Peptide Purity
The HPLC analysis is used to determine the proportion of the analysed material represented by the target BPC-157 peptide, reported as a percentage.
The analysis relates specifically to the sample submitted to Janoshik and the corresponding batch identified on this Certificate of Analysis.
The original Janoshik laboratory report is provided on this page so that the reported analytical information can be reviewed directly.